Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wordfence domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/sls2000.com.cn/wp-includes/functions.php on line 6260

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/sls2000.com.cn/wp-includes/functions.php on line 6260
电缆桥架厚度怎么确定?板材最小厚度解读 - 北京双龙盛电气制造有限公司

电缆桥架厚度怎么确定?板材最小厚度解读

内容目录

电缆桥架作为电力工程中重要的辅助设备,其板材厚度的选择关系到系统的安全稳定运行和投资成本。那么,电缆桥架的厚度该如何确定呢?

1. 厚度与强度和刚度的关系

电缆桥架需要承受自重和电缆载荷,抗弯刚度是评价其强度的关键指标。抗弯刚度与板材的弹性模量和惯性矩有关,增大厚度可以提高惯性矩,增强抗弯刚度。但是过薄的板材会导致强度和刚度不足,影响安全;过厚也会造成材料浪费。

2. 不同类型桥架厚度不同

由于形状和结构不同,各类型桥架的厚度要求也不相同。一般来说,平板托盘对板材厚度要求较高;增强型托盘通过工艺提升强度,可减小厚度;梯架由于截面型号的优化,厚度可相应减小。

3. 板材最小厚度应符合标准

行业标准对不同规格的桥架板材提出了最小厚度要求。这是基于大量结构计算和强度分析得出的结果,代表了必要的安全储备。板材厚度不应低于标准规定的最小值。

4. 区分不同载荷等级

桥架按允许载荷划分为不同等级。较高等级的桥架,其板材应相应增厚,以提供足够的强度和刚度。

5. 计算确定特殊情况的厚度

对于非标准规格或特殊载荷的桥架,可以通过结构计算确定板材合理的厚度,但不应低于标准的最小值。

综上所述,电缆桥架厚度的确定是一项综合分析的工作。一般应遵循标准规定的最小厚度要求,严格按照载荷等级选择匹配的厚度,确保电缆桥架具有足够的安全性能和经济性。

目前最常用的两个钢制桥架标准厚度要求如下

                                                                表9    桥架允许最小板材厚度                                   单位为毫米
托盘、梯架宽度 W允许最小板材厚度
钢制桥架玻璃钢制桥架铝合金制桥架
W≤1501.03.01.2
150<W≤3001.23.51.5
300<W≤5001.54.02.0
500<W≤8002.04.52.2
W>8002.25.02.5
          注1:连接板的厚度至少按托盘、梯架同等板厚选用,也可以选厚一个等级。
          注2:盖板的板厚可以按托盘、梯架的厚度选低一个等级。宽度W>400的玻璃钢制、铝合金制
                桥架,底板厚度允许    低于托盘、梯架侧板厚度,但必须加横档,横档中心距不应大于400 mm。 
          注3:采用特别结构型式桥架,板材厚度允许低于本表,但是安全载荷(SWL)应满足表11的要求。

《JBT 10216-2013 电控配电用电缆桥架》

槽宽≤150mm,槽体厚度≥1.0mm

槽宽>150mm且≤300mm,槽体厚度≥1.2mm  

槽宽>300mm且≤500mm,槽体厚度≥1.5mm

槽宽>500mm且≤800mm,槽体厚度≥2.0mm  

槽宽>800mm,槽体厚度≥2.2mm

根据标准《T/CECS 31-2017 钢制电缆桥架工程技术规程》,具体规定如下:

表3.5.5-1 各类托盘板材最小允许厚度 (mm)
托盘宽
B
平板型波纹底模压增强底
槽体盖板侧板波纹底板盖板槽体盖板
B<3001.2110.70.60.80.6
300≤B<50021.21.20.70.610.6
500≤B<80031.51.40.80.61.20.6
800、1000--1.50.80.61.50.6

槽宽<300mm,槽体厚度≥1.2mm,盖板厚度≥1.0mm

槽宽≥300mm,且<500mm,槽体厚度≥2.0mm,盖板厚度≥1.2mm

槽宽≥500mm,且<800mm时,槽体厚度≥3.0mm,盖板厚度≥1.5mm

槽宽为≥800mm,槽体厚度≥3.0mm(标准未写,默认取3.0mm),盖板厚度≥1.5mm

需要注意的是标准《T/CECS 31-2017 钢制电缆桥架工程技术规程》托盘和梯架量厚度不同,具体规定如下:

表3.5.5-3  普通梯架板材最小允许厚度 (mm)
梯架宽 B侧    板横    档盖    板
150<B≤3001.21.21.0 
300<B≤5001.51.51.2
500<B≤800221.5 
10002.52.52.0 

梯架宽>150mm,且≤300mm,梯架厚度≥2.0mm,盖板厚度≥1.2mm

梯架宽≥300mm,且<500mm,梯架厚度≥2.0mm,盖板厚度≥1.2mm

梯架宽≥500mm,且<800mm时,梯架厚度≥3.0mm,盖板厚度≥1.5mm

常见问题

问题1:什么因素会影响电缆桥架的板材厚度?

回答:主要包括所需的强度和刚度、桥架类型和形状、承载的荷重级别等。增大板材厚度可以提高强度和刚度,但也要考虑经济性。

问题2:承载荷不同的电缆桥架,板材厚度应如何选择?

回答:载荷越大的桥架,板材应相应增厚,提供足够的强度和刚度。

问题3:目前常见的电缆桥架标准对板材最小厚度有哪些规定?

回答:JBT 10216-2013和T/CECS 31-2017标准对不同规格桥架的最小厚度进行了规定。